Specification and characteristics : | |||
---|---|---|---|
Backing Specification | Membrane Specification | ||
Material | Polyester | Material | Cellulose Nitrate Polymer |
Thickness | 102 ± 5µm | Thickness | 105 ± 15µm (Membrane layer only) |
Colour | Transparent | Wicking Time | 160 ± 35 sec/40mm distance |
Wetting Time | ≤ 5 sec (10µ volume 0.3% BAS in PBS 0.01M pH 7.4) |
Roll Specification | |
---|---|
Roll Core | 76.5 mm = 3" (inner Diameter) |
Core Material | Plastic |
Available Membrane width | As desired |
Ordering Information | ||||
---|---|---|---|---|
Cat. No. | Rating | Wicking Time | Width | Length |
DE20/SX04 | 8 µm | 160 sec | 20 mm ± 0.3 | 100 ± 2 meter roll |
DE25/SX04 | 8 µm | 160 sec | 25 mm ± 0.3 | 100 ± 2 meter roll |
DE30/SX04 | 8 µm | 160 sec | 30 mm ± 0.3 | 100 ± 2 meter roll |
DE40/SX04 | 8 µm | 160 sec | 40 mm ± 0.3 | 100 ± 2 meter roll |
Custom dimension are also available on request
AXIVA - Nitrocellulose Membrane 140 sec (10µm) |
---|
This membrane is used for testing of Dengue, Malaria and for infection disease tests with serum etc.
Specification and characteristics : | |||
---|---|---|---|
Backing Specification | Membrane Specification | ||
Material | Polyester | Material | Cellulose Nitrate Polymer |
Thickness | 102 ± 5µm | Thickness | 105 ± 15µm (Membrane layer only) |
Colour | Transparent | Wicking Time | 140 ± 30 sec/40mm distance |
Wetting Time | ≤ 5 sec (10µ volume 0.3% BAS in PBS 0.01M pH 7.4) |
Roll Specification | |
---|---|
Roll Core | 76.5 mm = 3" (inner Diameter) |
Core Material | Plastic |
Available Membrane width | As desired |
Ordering Information | ||||
---|---|---|---|---|
Cat. No. | Rating | Wicking Time | Width | Length |
DF20/SX04 | 10 µm | 140 sec | 20 mm ± 0.3 | 100 ± 2 meter roll |
DF25/SX04 | 10 µm | 140 sec | 25 mm ± 0.3 | 100 ± 2 meter roll |
DF30/SX04 | 10 µm | 140 sec | 30 mm ± 0.3 | 100 ± 2 meter roll |
DF40/SX04 | 10 µm | 140 sec | 40 mm ± 0.3 | 100 ± 2 meter roll |
Custom dimension are also available on request
AXIVA - Nitrocellulose Membrane 120 sec (12µm) |
---|
This membrane is used for testing of hCG, and for infection disease tests with serum etc.
Specification and characteristics : | |||
---|---|---|---|
Backing Specification | Membrane Specification | ||
Material | Polyester | Material | Cellulose Nitrate Polymer |
Thickness | 102 ± 5µm | Thickness | 105 ± 15µm (Membrane layer only) |
Colour | Transparent | Wicking Time | 120 ± 28 sec/40mm distance |
Wetting Time | ≤ 5 sec (10µ volume 0.3% BAS in PBS 0.01M pH 7.4) |
Ordering Information | ||||
---|---|---|---|---|
Cat. No. | Rating | Wicking Time | Width | Length |
CG20/SX02 | 12 µm | 120 sec | 20 mm ± 0.3 | 100 ± 2 meter roll |
CG25/SX02 | 12 µm | 120 sec | 25 mm ± 0.3 | 100 ± 2 meter roll |
CG30/SX02 | 12 µm | 120 sec | 30 mm ± 0.3 | 100 ± 2 meter roll |
CG40/SX02 | 12 µm | 120 sec | 40 mm ± 0.3 | 100 ± 2 meter roll |
Custom dimension are also available on request
AXIVA - Nitrocellulose Membrane 110 sec (15µm) |
---|
This membrane is used for whole blood test and for Malaria tests. Due to larger pore size the wicking speed is fast and good for viscous or particle loaded sample.
Specification and characteristics : | |||
---|---|---|---|
Backing Specification | Membrane Specification | ||
Material | Polyester | Material | Cellulose Nitrate Polymer |
Thickness | 102 ± 5µm | Thickness | 105 ± 15µm (Membrane layer only) |
Colour | Transparent | Wicking Time | 110 ± 25 sec/40mm distance |
Wetting Time | ≤ 5 sec (10µ volume 0.3% BAS in PBS 0.01M pH 7.4) |
Ordering Information | ||||
---|---|---|---|---|
Cat. No. | Rating | Wicking Time | Width | Length |
CH20/SX05 | 15 µm | 110 sec | 20 mm ± 0.3 | 100 ± 2 meter roll |
CH25/SX05 | 15 µm | 110 sec | 25 mm ± 0.3 | 100 ± 2 meter roll |
CH30/SX05 | 15 µm | 110 sec | 30 mm ± 0.3 | 100 ± 2 meter roll |
CH40/SX05 | 15 µm | 110 sec | 40 mm ± 0.3 | 100 ± 2 meter roll |
AXIVA - Nitrocellulose Membrane 100 sec (15µm) |
---|
This membrane is used for HCG (Pregnancy Test)
Specification and characteristics : | |||
---|---|---|---|
Backing Specification | Membrane Specification | ||
Material | Polyester | Material | Cellulose Nitrate Polymer |
Thickness | 102 ± 5µm | Thickness | 105 ± 15µm (Membrane layer only) |
Colour | Transparent | Wicking Time | 100 ± 25 sec/40mm distance |
Wetting Time | ≤ 5 sec (10µ volume 0.3% BAS in PBS 0.01M pH 7.4) |
Ordering Information | ||||
---|---|---|---|---|
Cat. No. | Rating | Wicking Time | Width | Length |
CH20/SX01 | 15 µm | 100 sec | 20 mm ± 0.3 | 100 ± 2 meter roll |
CH25/SX01 | 15 µm | 100 sec | 25 mm ± 0.3 | 100 ± 2 meter roll |
CH30/SX01 | 15 µm | 100 sec | 30 mm ± 0.3 | 100 ± 2 meter roll |
CH40/SX01 | 15 µm | 100 sec | 40 mm ± 0.3 | 100 ± 2 meter roll |