FUME HOOD

AXIVA - Fume Hoods Double Walled

With remote operated service line. Metallic CRC sheet duly Powder Coated. Interior chemical resistant, durable, FRP or polypropylene integral work walls with Baffle arrangement. Worktop Chemical resistant splash & spillage proof "PP" or FRP or granite. Auxiliary type fume hood with all remote controlled service lines i.e. water supply, two ports for gas/vacuum & LPG gas. Two electrical sockets.

S. No. Design Structure Aerodynamic, Floor Mounteda
1. Airflow Type Automatic Bypass Type
2. Construction (Exterior) Powder coated G.I. or M.S. sheet
3. Construction (Interior) Chemical resistant, durable, Phenolic bonded resin sheet (PP) integral work walls (5mm thick).
4. Baffle arrangement 3 point suction system (for light, normal & heavy fumes) with baffle to ensure smooth and immediate exhaust of fumes.
5. Worktop Chemical resistant splash & spillage proof 'PP' worktop or Granite worktop.
6. Sink /Water tap with drain arrangement Worktop has PP sink for drainage with a water tap & drain arrangement
7. Sash (Shutter) Vertical rising counter - balanced 'Toughened Glass' sash (4mm thick). Smooth and light sash operation. Clear open able height = 700mm
8. Wet & Dry Service fittings Remotely operated color coded (as per international norms) for gas, water & vacuum connection
9. Lighting Fluorescent light (40 watt, 1 Nos.) with vapor - proof fitting to proper illumination
10. Electrical Utilities Electrical sockets 'Anchor' make (230 V, 5/15A, 50 Hz), with blower No./NC switch (for customer's starter) & light switch on front fascia
11. Chemical Storage Base Cabinet Base cabinet will be ready to receive the fume hood at its top. It has following features. Internal FRP lining to the cabinet walls. Two exhaust ports connected to the fume hood exhaust system internally. Two horizontal partitions to store chemicals. Double skin door with magnetic locking arrangement Overall Dimensions : 1000mm (W)x 600mm (D) x 800mm H)
12. Fire Extinguisher ABC dry power fire extinguisher (500gm)
13. Level Adjusting To adjust fume hood level by ± 10mm
S. No. Cat No. Working Table Size (LXWXH)
(a) AXMF-3 90cm x 75cm x 75cm (3ft x 2½ft x 2½ft)
(b) AXMF-4 120cm x 75cm x 75cm (4ft x 2½ft x 2½ft)
(c) AXMF-5 150cm x 75cm x 75cm (5ft x 2½ft x 2½ft)
(d) AXMF-6 180cm x 75cm x 75cm (6ft x 2½ft x 2½ft)

* Other sizes can be manufactured against requirement

Optional
(a) Fume duct PVC per running ft. (Pls suffix ED for Cat No.)
(b) Fume duct PVC with Glass Fibre internal Lining
(c) Grid at the back wall of working chamber to hold the glass apparatus (Pls. Suffix G for Cat No.)
(d) IQ/OQ/PQ/DQ certificates

Works good on most of the chemical fumes except Hydrochloric acid, Perchloric acid, Nitric acid Hydrofluoric acid. Please specify the acid fumes at the time of ordering