| AXIVA - Nitrocellulose Membrane 160 sec (8µm) |
|---|
This membrane is used for testing of urine Ab tests and for HbsAg serum test.
| Specification and characteristics : | |||
|---|---|---|---|
| Backing Specification | Membrane Specification | ||
| Material | Polyester | Material | Cellulose Nitrate Polymer |
| Thickness | 102 ± 5µm | Thickness | 105 ± 15µm (Membrane layer only) |
| Colour | Transparent | Wicking Time | 160 ± 35 sec/40mm distance |
| Wetting Time | ≤ 5 sec (10µ volume 0.3% BAS in PBS 0.01M pH 7.4) | ||
| Roll Specification | |
|---|---|
| Roll Core | 76.5 mm = 3" (inner Diameter) |
| Core Material | Plastic |
| Available Membrane width | As desired |
| Ordering Information | ||||
|---|---|---|---|---|
| Cat. No. | Rating | Wicking Time | Width | Length |
| DE20/SX04 | 8 µm | 160 sec | 20 mm ± 0.3 | 100 ± 2 meter roll |
| DE25/SX04 | 8 µm | 160 sec | 25 mm ± 0.3 | 100 ± 2 meter roll |
| DE30/SX04 | 8 µm | 160 sec | 30 mm ± 0.3 | 100 ± 2 meter roll |
| DE40/SX04 | 8 µm | 160 sec | 40 mm ± 0.3 | 100 ± 2 meter roll |
Custom dimension are also available on request
| AXIVA - Nitrocellulose Membrane 140 sec (10µm) |
|---|
This membrane is used for testing of Dengue, Malaria and for infection disease tests with serum etc.
| Specification and characteristics : | |||
|---|---|---|---|
| Backing Specification | Membrane Specification | ||
| Material | Polyester | Material | Cellulose Nitrate Polymer |
| Thickness | 102 ± 5µm | Thickness | 105 ± 15µm (Membrane layer only) |
| Colour | Transparent | Wicking Time | 140 ± 30 sec/40mm distance |
| Wetting Time | ≤ 5 sec (10µ volume 0.3% BAS in PBS 0.01M pH 7.4) | ||
| Roll Specification | |
|---|---|
| Roll Core | 76.5 mm = 3" (inner Diameter) |
| Core Material | Plastic |
| Available Membrane width | As desired |
| Ordering Information | ||||
|---|---|---|---|---|
| Cat. No. | Rating | Wicking Time | Width | Length |
| DF20/SX04 | 10 µm | 140 sec | 20 mm ± 0.3 | 100 ± 2 meter roll |
| DF25/SX04 | 10 µm | 140 sec | 25 mm ± 0.3 | 100 ± 2 meter roll |
| DF30/SX04 | 10 µm | 140 sec | 30 mm ± 0.3 | 100 ± 2 meter roll |
| DF40/SX04 | 10 µm | 140 sec | 40 mm ± 0.3 | 100 ± 2 meter roll |
Custom dimension are also available on request
| AXIVA - Nitrocellulose Membrane 120 sec (12µm) |
|---|
This membrane is used for testing of hCG, and for infection disease tests with serum etc.
| Specification and characteristics : | |||
|---|---|---|---|
| Backing Specification | Membrane Specification | ||
| Material | Polyester | Material | Cellulose Nitrate Polymer |
| Thickness | 102 ± 5µm | Thickness | 105 ± 15µm (Membrane layer only) |
| Colour | Transparent | Wicking Time | 120 ± 28 sec/40mm distance |
| Wetting Time | ≤ 5 sec (10µ volume 0.3% BAS in PBS 0.01M pH 7.4) | ||
| Ordering Information | ||||
|---|---|---|---|---|
| Cat. No. | Rating | Wicking Time | Width | Length |
| CG20/SX02 | 12 µm | 120 sec | 20 mm ± 0.3 | 100 ± 2 meter roll |
| CG25/SX02 | 12 µm | 120 sec | 25 mm ± 0.3 | 100 ± 2 meter roll |
| CG30/SX02 | 12 µm | 120 sec | 30 mm ± 0.3 | 100 ± 2 meter roll |
| CG40/SX02 | 12 µm | 120 sec | 40 mm ± 0.3 | 100 ± 2 meter roll |
Custom dimension are also available on request
| AXIVA - Nitrocellulose Membrane 110 sec (15µm) |
|---|
This membrane is used for whole blood test and for Malaria tests. Due to larger pore size the wicking speed is fast and good for viscous or particle loaded sample.
| Specification and characteristics : | |||
|---|---|---|---|
| Backing Specification | Membrane Specification | ||
| Material | Polyester | Material | Cellulose Nitrate Polymer |
| Thickness | 102 ± 5µm | Thickness | 105 ± 15µm (Membrane layer only) |
| Colour | Transparent | Wicking Time | 110 ± 25 sec/40mm distance |
| Wetting Time | ≤ 5 sec (10µ volume 0.3% BAS in PBS 0.01M pH 7.4) | ||
| Ordering Information | ||||
|---|---|---|---|---|
| Cat. No. | Rating | Wicking Time | Width | Length |
| CH20/SX05 | 15 µm | 110 sec | 20 mm ± 0.3 | 100 ± 2 meter roll |
| CH25/SX05 | 15 µm | 110 sec | 25 mm ± 0.3 | 100 ± 2 meter roll |
| CH30/SX05 | 15 µm | 110 sec | 30 mm ± 0.3 | 100 ± 2 meter roll |
| CH40/SX05 | 15 µm | 110 sec | 40 mm ± 0.3 | 100 ± 2 meter roll |
| AXIVA - Nitrocellulose Membrane 100 sec (15µm) |
|---|
This membrane is used for HCG (Pregnancy Test)
| Specification and characteristics : | |||
|---|---|---|---|
| Backing Specification | Membrane Specification | ||
| Material | Polyester | Material | Cellulose Nitrate Polymer |
| Thickness | 102 ± 5µm | Thickness | 105 ± 15µm (Membrane layer only) |
| Colour | Transparent | Wicking Time | 100 ± 25 sec/40mm distance |
| Wetting Time | ≤ 5 sec (10µ volume 0.3% BAS in PBS 0.01M pH 7.4) | ||
| Ordering Information | ||||
|---|---|---|---|---|
| Cat. No. | Rating | Wicking Time | Width | Length |
| CH20/SX01 | 15 µm | 100 sec | 20 mm ± 0.3 | 100 ± 2 meter roll |
| CH25/SX01 | 15 µm | 100 sec | 25 mm ± 0.3 | 100 ± 2 meter roll |
| CH30/SX01 | 15 µm | 100 sec | 30 mm ± 0.3 | 100 ± 2 meter roll |
| CH40/SX01 | 15 µm | 100 sec | 40 mm ± 0.3 | 100 ± 2 meter roll |
Custom dimension are also available on request